TT slabs

 

Double-T floor units in prestressed concrete have a ribbed cross-section and a smooth under face. The units are mainly used for greater spans and imposed loading. The units are manufactured with two standard widths: 2400 and 3000 mm. However, the units can also be manufactured in a smaller width to meet the requirements of a particular project. The minimum width is 1500 mm. The standard profile is given below.

7_02.jpg

 

The ends of the units can be notched to reduce the overall structural depth. A structural topping can be used to ensure both vertical shear transfer between adjacent units and horizontal diaphragm action in the floor plate. The standard double-T units have a minimum fire resistance of 60 to 120 minutes. Anchor rails can be cast into the soffits of the webs.

 

 

Technical characteristics

Characteristics TT-2400

Profile

h mm

b mm

b1 mm

b2 mm

b0 mm

Weight kg / m2

Fire resistence 60 min
TT 2400 - 500 / 120
TT 2400 – 800 / 120

500
800

2390
2390

1068
1143

661
623

120
120

261
360

Fire resistence 90 min
TT 2400 - 500 / 150
TT 2400 – 800 / 150

500
800

2390
2390

1084
1159

671
615

150
150

287
405

Fire resistence 120 min
TT 2400 - 500 / 200
TT 2400 – 800 / 200

500
800

2390
2390

1100
1175

645
607

200
200

332
481


Characteristics TT-3000

Profile

h mm

b mm

b1 mm

b2 mm

b0 mm  

Weight kg / m2

Fire resistence 60 min
TT 3000 - 500 / 120
TT 3000 – 800 / 120

500
800

2990
2990

1368
1443

811
773

120
120

232
313

Fire resistence 90 min
TT 3000 - 500 / 150
TT 3000 – 800 / 150

500
800

2990
2990

1384
1459

821
765

150
150

254
349

Fire resistence 120 min
TT 3000 - 500 / 200
TT 3000 – 800 / 200

500
800

2990
2990

1400
1475

795
757

200
200

290
409

 

The performance curves give the variance of load bearing capacity dependently on the span length.

 

Performance curves TT-2400

Padidinti

Performance curves TT-3000

Padidinti


Support connections

Connections between TT floors and supporting beams are made through lapping reinforcement in the structural topping or by bars welded to plates fully anchored in the units. There is possible connection placed below.

f4ebb699a1_01.JPG

Connection through structural topping

Connections between TT floors and supporting beams are made through lapping reinforcement in the structural topping or by bars welded to plates fully anchored in the units. There is possible connection placed below.

aedab4ef81_01.JPG

Conncetions between adjacent units

 

1afddc83de_01.JPG

Welded adjacment

 

Holes and voids

Holes may be formed in double-T slabs in the positions shown in the figure. The maximum dimensions are given in the table.

3a221d3487_01.JPG

 

l / b 

TT - 2400

TT - 3000

Center

1000 / 630

1000 / 930

Edge

1000 / 320

1000 / 460

Corner

1000 / 320

1000 / 460

The TT-units should always be stacked one above the other and the soft wood bearers placed at the slab ends should also be one above the other. This also applies when loading on the truck.

The units are provided with four cast-in lifting hooks, each over the line of the webs. The slings or chains should be long enough to enable an inclination to the slab of not less than 600.